Un onduleur peut prélever de l'énergie de la batterie lorsque sa sortie CA est activée et qu'aucun appareil n'est branché. Cette consommation à vide revêt une importance particulière lorsque le système reste inactif pendant de nombreuses heures en attendant une faible charge, comme c'est le cas dans un chalet sans surveillance ou dans une installation de secours fonctionnant de nuit.
Convert the stated watts into energy over the expected operating hours before comparing models. Then check the operating mode used for the specification. An ECO-mode figure may describe a different service from continuously available AC power.
Put the daily loss beside the useful demand
Take two hypothetical inverters drawing 12 W and 35 W with AC enabled and no load. If each remains in that state for 16 hours, their energy use would be 192 Wh and 560 Wh respectively. The difference is 368 Wh a day.
For a system with small daily loads, that difference can affect both the battery allowance and the energy needed to recharge it. It does not establish which inverter is better overall: continuous output, starting performance, operating modes and efficiency under the actual load still need comparison.
| Hypothetical no-load draw | 8 hours | 16 hours | 24 hours |
|---|---|---|---|
| 12 W | 96 Wh | 192 Wh | 288 Wh |
| 35 W | 280 Wh | 560 Wh | 840 Wh |
The calculation is simply watts multiplied by hours. These figures illustrate the method and are not LAINERGY product measurements.

“Standby” needs a definition
Ask what remains active during the quoted standby test. The AC inverter may be running, periodically searching for a load, or disabled while communications remain available. A hybrid system may also have grid-side consumption that is absent from a battery-only figure.
Victron’s Sun Inverter specifications give separate zero-load and ECO-mode figures. The distinction is a useful prompt for your supplier: request consumption for the mode the customer will actually use, along with the voltage and enabled functions.
Check small loads before enabling search mode
A search or ECO mode can reduce consumption by changing how the inverter waits for a load. Check its load-detection threshold and wake-up behavior against the devices it will supply.
A router, clock or control device may need uninterrupted power even though its demand is small. Ask the installer to test the actual device in the intended mode, including recovery after it is unplugged or restarted. Do not assume that a setting which works for a lamp will also suit communications equipment.
Where continuous service is required, compare consumption with that service enabled. A lower number from a different mode does not represent the same customer requirement.
Avoid counting the loss twice
If a measured runtime test already includes the inverter’s own consumption, do not subtract it again from the result. Similarly, an efficiency curve may already include some internal losses. Establish the measurement boundary before adding a fixed allowance to a sizing model.
For a simple planning model, separate hours with the inverter idle from hours supplying loads. Use the documented no-load value for the first period and appropriate measured input or efficiency data for the second. Our backup battery sizing article provides the load-energy calculation to which those allowances belong.
What to request in a sample evaluation
Ask for a record of DC input power with AC enabled and no load, followed by input and output power at representative small loads. Record battery voltage, temperature, mode, firmware and monitoring accessories. For fluctuating consumption, an energy measurement over a stated period is more useful than one screen reading.
Repeat the check with the customer’s essential low-power device. Note whether the output remains available and how the device behaves after a restart. Keep those results with the approved sample specification so a later firmware or hardware revision can be reviewed.
When requesting off-grid inverters from LAINERGY, include the overnight load and the hours AC must remain available. That lets the quotation address the energy used between operating periods as well as the inverter’s headline output rating.